-40%

Phase Matrix 346A 46 GHz Microwave Frequency Counter w/Opt 01 HP 53152A/001

$ 3167.99

Availability: 50 in stock
  • All returns accepted: ReturnsNotAccepted
  • Brand: Phase Matrix
  • MPN: 346A
  • Configuration: 01
  • Condition: This unit ships fully tested and guaranteed to work for 30-days, parts and labor, excluding freight. There are various scuffs/scratches and some discoloration in certain spots of the case.
  • Frequency Range: 10 Hz - 46 GHz
  • Model: 346A

    Description

    Phase Matrix 346A 46 GHz Microwave Frequency Counter with Option 01 - Same as HP/Keysight Model 53152A with Option 001
    Comes with what you see in the pictures. If you don't see it, you probably won't get it.
    Specifications are from Phase Matrix and may vary slightly due to upgrades, options, or revisions this unit may or may not have.
    This unit ships fully tested and guaranteed to work for 30-days, parts and labor, excluding freight.
    The Unit's Serial Number Tag & Information Reads:
    Model Number:
    346A
    Serial Number:
    34604-0149
    Option:
    01 - Oven Time Base
    Power Requirements:
    100-130 VAC, 50/60/400 Hz, 75 VA. 200-240 VAC, 50-60 Hz, 75 VA.
    CE Marked:
    Yes
    Description:
    The Phase Matrix 346A Microwave Frequency Counter is capable of measuring frequencies from 10 Hz to 125 MHz on Channel 1 and  50 MHz to 46 GHz on Channel 2. The counter is also capable of measuring power on Channel 2 (in the same frequency ranges). The counter has a maximum frequency resolution of 1 Hz.
    The counter also provides GPIB and RS-232 serial interfaces and is suitable for bench-top and ATE operation.
    The basic measurement functions of the counter include Frequency, Relative Frequency, Frequency Offset, and Power (including Power Offset and Relative Power). All of these features are acessible from the front panel and over the GPIB and RS-232 interfaces.
    The counter includes the following additional measurement functions and features that are designed specifically for manufacturing and service applications:
    1, 2, 5, and 10 MHz external-reference capability
    Optional high-stability oven oscillator for high-accuracy needs and lengthened calibration cycles
    Frequency- and power-offset capabilities for rleative measurements
    SCPI programming capability
    Programmable control is performed via a GPIB or RS-232 serial interface.
    Specifications:
    Frequency Range:
    Channel 1 - Normal Mode:
    10 - 125 MHz
    Channel 1 - Low Pass Filter Enabled:
    10 Hz - 50 kHz
    Channel 2:
    50 MHz - 46 GHz
    Sensitivity:
    Channel 1:
    10 - 30 Hz:
    40 mV rms
    30 Hz - 125 MHz:
    25 mV rms
    Channel 2:
    50 - 300 MHz:
    -20 dBm
    0.3 - 12.4 GHz:
    -33 dBm
    12.4 - 18 GHz:
    -30 dBm
    18 - 20 GHz:
    -27 dBm
    20 - 26.5 GHz:
    -27 dBm
    26.5 - 40 GHz:
    -23 dBm
    40 - 46 GHz:
    -17 dBm
    Maximum Input:
    Channel 1:
    2 V
    rms
    Channel 2:
    50 MHz - 2 GHz:
    +5 dBm
    2 - 46 GHz:
    +13 dBm
    Damage Level:
    Channel 1:
    120 V (dc + ac pk) linearly derated to 5 V
    rms
    at 125 MHz
    Channel 2:
    +27 dBm
    Impedance (Nominal):
    Channel 1:
    1 MΩ/60 pF
    Channel 2:
    50 Ω
    Connector:
    Channel 1:
    BNC female
    Channel 2:
    2.92 mm removable, female
    SWR - Channel 2:
    50 - 300 MHz:
    1.5:1 typical
    0.3 - 10 GHz:
    2.0:1 typical
    10 - 20 GHz:
    3.0:1 typical
    20 - 26.5 GHz:
    2.5:1 typical
    26.5 - 46 GHz:
    2.5:1 typical
    Coupling:
    Channel 1:
    ac
    Channel 2:
    ac
    Acquisition Time (Typical - 1 MHz FM rate, power measurement off):
    Channel 1:
    N/A
    Channel 2 (FM Auto/FM Off):
    140 ms/115 ms
    Resolution Selection:
    Channel 1/Channel 2:
    1 Hz to 1 MHz
    Emissions (Typical - "kickback noise"):
    Channel 1:
    N/A
    Channel 2 (measuring/no input):
    -40 dBm/< -70 dBm
    Residual Stability*:
    Channel 1:
    N/A
    Channel 2:
    1.25 LSD rms
    Accuracy:
    Channel 1/Channel 2 (LSD = resolution selected):
    ±1 LSD ±residual stability ±timebase error x frequency
    Measurement Time (Typical):
    Channel 1:
    1/Resolution + 20 ms
    Channel 2:
    1/Resolution + Acquisition time + 20 ms
    FM Tolerance:
    Channel 1:
    N/A
    Channel 2 - FM Auto:
    Channel 2 - FM Off:
    1 MHz p-p @ 10 MHz Rate
    AM Tolerance:
    Channel 1, Channel 2:
    Any index provided minimum signal level is not less than sensitivity:
    Amplitude Discrimination:
    Channel 1:
    N/A
    Channel 2:
    Below 300 MHz:
    N/A
    Above 300 MHz:
    Automatically measures the largest signal present provided signal is > 10 dB (typical) above anys ignal separated by less than 75 MHz; > 20 dB (typical) above any signal separated by more than 75 MHz.
    Power Measurement:
    Channel 1:
    N/A
    Channel 2:
    Range:
    Counter sensitivity to +7 dBm
    Acuracy at input connector (0 dBm to -20 dBm):
    Counter sensitivity to +7 dBm
    0.05 - 12.4 GHz:
    ±1.5 dB
    12.4 = 20 GHz:
    ±1.5 dB
    20 - 26.5 GHz:
    N/A
    26.5 - 46 GHz:
    N/A
    Resolution:
    0.01 dB
    Display:
    dBm or milliwatts/microwatts
    Timebase:
    Frequency:
    10 MHz
    Output:
    10 MHz sine wave, 1 Vrms into 50 Ω
    External Timebase Input:
    1, 2, 5, 10 MHz; 1 to 5 Vrms into 50 Ω
    Connector:
    BNC female located on rear panel
    Internal Timebase Stability - Oven (Option 01):
    Aging Rate:
    Per Day:
    < 5 x 10
    -8
    Per Month:
    < 1.5 x 10
    -8
    Short Term:
    < 2 x 10
    -10
    (1 sec. avg. time)
    Line Variation:
    < 1 x 10
    -10
    (±10%)
    Warm-Up:
    < 1 x 10
    -8
    within 5 min. after turn-on at 25°C
    Temperature Stability:
    < 1 x 10
    -8
    General Specifications:
    Save and Recall:
    Up to 9 complete instrument setups may be saved and later recalled. These setups are retained when power is removed.
    Sample Rate:
    User-selectable Fast (nominally 20 ms between readings), Medium (nominally 250 ms between readings), Slow (nominally 1 s between readings) and Hold.
    Self Test:
    Internal memory and count circuitry automatically tested at startup, via menu selection, or remotely. Error messages displayed to indicate failed tests.
    Size:
    213 mm W x 88.5 mm H x 300 mm D
    Operating Temperature:
    0 - 55°C
    Weight:
    4 kg.
    Programming:
    GPIB (IEEE-488.1-1987, IEEE-488.2-1987) or RS-232C
    Language:
    SCPI-1992.0 (Standard Commands for Programmable Instruments)
    RS-232C Rates:
    User-selectable 2400 to 19200 baud.
    Power Supply:
    AC:
    90-132 VAC; 47.5-66 Hz or 360-440 Hz. 216-264 VAC; 47.5-66 Hz. Line selection automatic. 75 VA max. (25 W typ.)
    Math Functions:
    Offset:
    Last reading and/or entered offset to reading for either power or frequency
    Averaging:
    1 to 99 measurement running average
    Cable Loss Compensation:
    Offsets power reading via linear interpolation or user-entered attenuations with up to 9 independetn frequency points
    Safety:
    Designed in compliance with IEC-1010, CAN/CSA 1010.1
    EMC:
    Designed in compliance with IEC-11, EN50082-1, IEC801-2, -3, -4.
    For Domestic Customers: Packaging, handling, and order processing included in shipping in all domestic shipments as quoted by the shipping calculator. For International Customers there is a .00 minimum for insurance, packaging, handling, and order processing. International shipping to be determined by destination.
    Prior to shipment I will need to know the following information (filled out on a form that I will send you) for International Customers or Packages/Freight being Forwarded internationally. International customers may also be subject to a freight forwarder form if applicable.:
    (1) Are you the end-user of this item?
    (2) If you are not the ultimate end-user of the item, please state the ultimate end user's name.
    (3) What is the ultimate country destination?
    02/05/21