Description
Phase Matrix 346A 46 GHz Microwave Frequency Counter with Option 01 - Same as HP/Keysight Model 53152A with Option 001Comes with what you see in the pictures. If you don't see it, you probably won't get it.
Specifications are from Phase Matrix and may vary slightly due to upgrades, options, or revisions this unit may or may not have.
This unit ships fully tested and guaranteed to work for 30-days, parts and labor, excluding freight.
The Unit's Serial Number Tag & Information Reads:
Model Number:
346A
Serial Number:
34604-0149
Option:
01 - Oven Time Base
Power Requirements:
100-130 VAC, 50/60/400 Hz, 75 VA. 200-240 VAC, 50-60 Hz, 75 VA.
CE Marked:
Yes
Description:
The Phase Matrix 346A Microwave Frequency Counter is capable of measuring frequencies from 10 Hz to 125 MHz on Channel 1 and 50 MHz to 46 GHz on Channel 2. The counter is also capable of measuring power on Channel 2 (in the same frequency ranges). The counter has a maximum frequency resolution of 1 Hz.
The counter also provides GPIB and RS-232 serial interfaces and is suitable for bench-top and ATE operation.
The basic measurement functions of the counter include Frequency, Relative Frequency, Frequency Offset, and Power (including Power Offset and Relative Power). All of these features are acessible from the front panel and over the GPIB and RS-232 interfaces.
The counter includes the following additional measurement functions and features that are designed specifically for manufacturing and service applications:
1, 2, 5, and 10 MHz external-reference capability
Optional high-stability oven oscillator for high-accuracy needs and lengthened calibration cycles
Frequency- and power-offset capabilities for rleative measurements
SCPI programming capability
Programmable control is performed via a GPIB or RS-232 serial interface.
Specifications:
Frequency Range:
Channel 1 - Normal Mode:
10 - 125 MHz
Channel 1 - Low Pass Filter Enabled:
10 Hz - 50 kHz
Channel 2:
50 MHz - 46 GHz
Sensitivity:
Channel 1:
10 - 30 Hz:
40 mV rms
30 Hz - 125 MHz:
25 mV rms
Channel 2:
50 - 300 MHz:
-20 dBm
0.3 - 12.4 GHz:
-33 dBm
12.4 - 18 GHz:
-30 dBm
18 - 20 GHz:
-27 dBm
20 - 26.5 GHz:
-27 dBm
26.5 - 40 GHz:
-23 dBm
40 - 46 GHz:
-17 dBm
Maximum Input:
Channel 1:
2 V
rms
Channel 2:
50 MHz - 2 GHz:
+5 dBm
2 - 46 GHz:
+13 dBm
Damage Level:
Channel 1:
120 V (dc + ac pk) linearly derated to 5 V
rms
at 125 MHz
Channel 2:
+27 dBm
Impedance (Nominal):
Channel 1:
1 MΩ/60 pF
Channel 2:
50 Ω
Connector:
Channel 1:
BNC female
Channel 2:
2.92 mm removable, female
SWR - Channel 2:
50 - 300 MHz:
1.5:1 typical
0.3 - 10 GHz:
2.0:1 typical
10 - 20 GHz:
3.0:1 typical
20 - 26.5 GHz:
2.5:1 typical
26.5 - 46 GHz:
2.5:1 typical
Coupling:
Channel 1:
ac
Channel 2:
ac
Acquisition Time (Typical - 1 MHz FM rate, power measurement off):
Channel 1:
N/A
Channel 2 (FM Auto/FM Off):
140 ms/115 ms
Resolution Selection:
Channel 1/Channel 2:
1 Hz to 1 MHz
Emissions (Typical - "kickback noise"):
Channel 1:
N/A
Channel 2 (measuring/no input):
-40 dBm/< -70 dBm
Residual Stability*:
Channel 1:
N/A
Channel 2:
1.25 LSD rms
Accuracy:
Channel 1/Channel 2 (LSD = resolution selected):
±1 LSD ±residual stability ±timebase error x frequency
Measurement Time (Typical):
Channel 1:
1/Resolution + 20 ms
Channel 2:
1/Resolution + Acquisition time + 20 ms
FM Tolerance:
Channel 1:
N/A
Channel 2 - FM Auto:
Channel 2 - FM Off:
1 MHz p-p @ 10 MHz Rate
AM Tolerance:
Channel 1, Channel 2:
Any index provided minimum signal level is not less than sensitivity:
Amplitude Discrimination:
Channel 1:
N/A
Channel 2:
Below 300 MHz:
N/A
Above 300 MHz:
Automatically measures the largest signal present provided signal is > 10 dB (typical) above anys ignal separated by less than 75 MHz; > 20 dB (typical) above any signal separated by more than 75 MHz.
Power Measurement:
Channel 1:
N/A
Channel 2:
Range:
Counter sensitivity to +7 dBm
Acuracy at input connector (0 dBm to -20 dBm):
Counter sensitivity to +7 dBm
0.05 - 12.4 GHz:
±1.5 dB
12.4 = 20 GHz:
±1.5 dB
20 - 26.5 GHz:
N/A
26.5 - 46 GHz:
N/A
Resolution:
0.01 dB
Display:
dBm or milliwatts/microwatts
Timebase:
Frequency:
10 MHz
Output:
10 MHz sine wave, 1 Vrms into 50 Ω
External Timebase Input:
1, 2, 5, 10 MHz; 1 to 5 Vrms into 50 Ω
Connector:
BNC female located on rear panel
Internal Timebase Stability - Oven (Option 01):
Aging Rate:
Per Day:
< 5 x 10
-8
Per Month:
< 1.5 x 10
-8
Short Term:
< 2 x 10
-10
(1 sec. avg. time)
Line Variation:
< 1 x 10
-10
(±10%)
Warm-Up:
< 1 x 10
-8
within 5 min. after turn-on at 25°C
Temperature Stability:
< 1 x 10
-8
General Specifications:
Save and Recall:
Up to 9 complete instrument setups may be saved and later recalled. These setups are retained when power is removed.
Sample Rate:
User-selectable Fast (nominally 20 ms between readings), Medium (nominally 250 ms between readings), Slow (nominally 1 s between readings) and Hold.
Self Test:
Internal memory and count circuitry automatically tested at startup, via menu selection, or remotely. Error messages displayed to indicate failed tests.
Size:
213 mm W x 88.5 mm H x 300 mm D
Operating Temperature:
0 - 55°C
Weight:
4 kg.
Programming:
GPIB (IEEE-488.1-1987, IEEE-488.2-1987) or RS-232C
Language:
SCPI-1992.0 (Standard Commands for Programmable Instruments)
RS-232C Rates:
User-selectable 2400 to 19200 baud.
Power Supply:
AC:
90-132 VAC; 47.5-66 Hz or 360-440 Hz. 216-264 VAC; 47.5-66 Hz. Line selection automatic. 75 VA max. (25 W typ.)
Math Functions:
Offset:
Last reading and/or entered offset to reading for either power or frequency
Averaging:
1 to 99 measurement running average
Cable Loss Compensation:
Offsets power reading via linear interpolation or user-entered attenuations with up to 9 independetn frequency points
Safety:
Designed in compliance with IEC-1010, CAN/CSA 1010.1
EMC:
Designed in compliance with IEC-11, EN50082-1, IEC801-2, -3, -4.
For Domestic Customers: Packaging, handling, and order processing included in shipping in all domestic shipments as quoted by the shipping calculator. For International Customers there is a .00 minimum for insurance, packaging, handling, and order processing. International shipping to be determined by destination.
Prior to shipment I will need to know the following information (filled out on a form that I will send you) for International Customers or Packages/Freight being Forwarded internationally. International customers may also be subject to a freight forwarder form if applicable.:
(1) Are you the end-user of this item?
(2) If you are not the ultimate end-user of the item, please state the ultimate end user's name.
(3) What is the ultimate country destination?
02/05/21